Exposes an additional logger that uses the test's root logger as the parent for any TestCase instances constructor by the hook. The fixture logger still continues to be the parent of the hook logger. Also changes the CleanEveryN hook to explicitly get marked as a failure if a ServerFailure exception is thrown, rather than relying on TestReport.combine() to do so implicitly.
297 lines
11 KiB
Python
297 lines
11 KiB
Python
"""
|
|
Driver of the test execution framework.
|
|
"""
|
|
|
|
from __future__ import absolute_import
|
|
|
|
import threading
|
|
import time
|
|
|
|
from . import fixtures
|
|
from . import hooks as _hooks
|
|
from . import job as _job
|
|
from . import report as _report
|
|
from . import testcases
|
|
from .. import config as _config
|
|
from .. import errors
|
|
from .. import utils
|
|
from ..core import network
|
|
from ..utils import queue as _queue
|
|
|
|
|
|
class TestSuiteExecutor(object):
|
|
"""
|
|
Executes a test suite.
|
|
|
|
Responsible for setting up and tearing down the fixtures that the
|
|
tests execute against.
|
|
"""
|
|
|
|
_TIMEOUT = 24 * 60 * 60 # =1 day (a long time to have tests run)
|
|
|
|
def __init__(self,
|
|
exec_logger,
|
|
suite,
|
|
config=None,
|
|
fixture=None,
|
|
hooks=None):
|
|
"""
|
|
Initializes the TestSuiteExecutor with the test suite to run.
|
|
"""
|
|
self.logger = exec_logger
|
|
|
|
if _config.SHELL_CONN_STRING is not None:
|
|
# Specifying the shellConnString command line option should override the fixture
|
|
# specified in the YAML configuration to be the no-op fixture.
|
|
self.fixture_config = {"class": fixtures.NOOP_FIXTURE_CLASS}
|
|
else:
|
|
self.fixture_config = fixture
|
|
|
|
self.hooks_config = utils.default_if_none(hooks, [])
|
|
self.test_config = utils.default_if_none(config, {})
|
|
|
|
self._suite = suite
|
|
|
|
# Only start as many jobs as we need. Note this means that the number of jobs we run may not
|
|
# actually be _config.JOBS or self._suite.options.num_jobs.
|
|
jobs_to_start = self._suite.options.num_jobs
|
|
num_tests = len(suite.tests)
|
|
|
|
if num_tests < jobs_to_start:
|
|
self.logger.info(
|
|
"Reducing the number of jobs from %d to %d since there are only %d test(s) to run.",
|
|
self._suite.options.num_jobs, num_tests, num_tests)
|
|
jobs_to_start = num_tests
|
|
|
|
# Must be done after getting buildlogger configuration.
|
|
self._jobs = [self._make_job(job_num) for job_num in xrange(jobs_to_start)]
|
|
|
|
def run(self):
|
|
"""
|
|
Executes the test suite.
|
|
|
|
Any exceptions that occur during setting up or tearing down a
|
|
fixture are propagated.
|
|
"""
|
|
|
|
self.logger.info("Starting execution of %ss...", self._suite.test_kind)
|
|
|
|
return_code = 0
|
|
teardown_flag = None
|
|
try:
|
|
if not self._setup_fixtures():
|
|
return_code = 2
|
|
return
|
|
|
|
num_repeats = self._suite.options.num_repeats
|
|
while num_repeats > 0:
|
|
test_queue = self._make_test_queue()
|
|
|
|
partial_reports = [job.report for job in self._jobs]
|
|
self._suite.record_test_start(partial_reports)
|
|
|
|
# Have the Job threads destroy their fixture during the final repetition after they
|
|
# finish running their last test. This avoids having a large number of processes
|
|
# still running if an Evergreen task were to time out from a hang/deadlock being
|
|
# triggered.
|
|
teardown_flag = threading.Event() if num_repeats == 1 else None
|
|
(report, interrupted) = self._run_tests(test_queue, teardown_flag)
|
|
|
|
self._suite.record_test_end(report)
|
|
|
|
# If the user triggered a KeyboardInterrupt, then we should stop.
|
|
if interrupted:
|
|
raise errors.UserInterrupt("Received interrupt from user")
|
|
|
|
if teardown_flag and teardown_flag.is_set():
|
|
return_code = 2
|
|
|
|
sb = [] # String builder.
|
|
self._suite.summarize_latest(sb)
|
|
self.logger.info("Summary: %s", "\n ".join(sb))
|
|
|
|
if not report.wasSuccessful():
|
|
return_code = 1
|
|
if self._suite.options.fail_fast:
|
|
break
|
|
|
|
# Clear the report so it can be reused for the next execution.
|
|
for job in self._jobs:
|
|
job.report.reset()
|
|
num_repeats -= 1
|
|
finally:
|
|
if not teardown_flag:
|
|
if not self._teardown_fixtures():
|
|
return_code = 2
|
|
self._suite.return_code = return_code
|
|
|
|
def _setup_fixtures(self):
|
|
"""
|
|
Sets up a fixture for each job.
|
|
"""
|
|
|
|
# We reset the internal state of the PortAllocator before calling job.fixture.setup() so
|
|
# that ports used by the fixture during a test suite run earlier can be reused during this
|
|
# current test suite.
|
|
network.PortAllocator.reset()
|
|
|
|
for job in self._jobs:
|
|
try:
|
|
job.fixture.setup()
|
|
except:
|
|
self.logger.exception(
|
|
"Encountered an error while setting up %s.", job.fixture)
|
|
return False
|
|
|
|
# Once they have all been started, wait for them to become available.
|
|
for job in self._jobs:
|
|
try:
|
|
job.fixture.await_ready()
|
|
except:
|
|
self.logger.exception(
|
|
"Encountered an error while waiting for %s to be ready", job.fixture)
|
|
return False
|
|
return True
|
|
|
|
def _run_tests(self, test_queue, teardown_flag):
|
|
"""
|
|
Starts a thread for each Job instance and blocks until all of
|
|
the tests are run.
|
|
|
|
Returns a (combined report, user interrupted) pair, where the
|
|
report contains the status and timing information of tests run
|
|
by all of the threads.
|
|
"""
|
|
|
|
threads = []
|
|
interrupt_flag = threading.Event()
|
|
user_interrupted = False
|
|
try:
|
|
# Run each Job instance in its own thread.
|
|
for job in self._jobs:
|
|
t = threading.Thread(target=job,
|
|
args=(test_queue, interrupt_flag),
|
|
kwargs=dict(teardown_flag=teardown_flag))
|
|
# Do not wait for tests to finish executing if interrupted by the user.
|
|
t.daemon = True
|
|
t.start()
|
|
threads.append(t)
|
|
# SERVER-24729 Need to stagger when jobs start to reduce I/O load if there
|
|
# are many of them. Both the 5 and the 10 are arbitrary.
|
|
# Currently only enabled on Evergreen.
|
|
if _config.STAGGER_JOBS and len(threads) >= 5:
|
|
time.sleep(10)
|
|
|
|
joined = False
|
|
while not joined:
|
|
# Need to pass a timeout to join() so that KeyboardInterrupt exceptions
|
|
# are propagated.
|
|
joined = test_queue.join(TestSuiteExecutor._TIMEOUT)
|
|
except (KeyboardInterrupt, SystemExit):
|
|
interrupt_flag.set()
|
|
user_interrupted = True
|
|
else:
|
|
# Only wait for all the Job instances if not interrupted by the user.
|
|
for t in threads:
|
|
t.join()
|
|
|
|
reports = [job.report for job in self._jobs]
|
|
combined_report = _report.TestReport.combine(*reports)
|
|
|
|
# We cannot return 'interrupt_flag.is_set()' because the interrupt flag can be set by a Job
|
|
# instance if a test fails and it decides to drain the queue. We only want to raise a
|
|
# StopExecution exception in TestSuiteExecutor.run() if the user triggered the interrupt.
|
|
return (combined_report, user_interrupted)
|
|
|
|
def _teardown_fixtures(self):
|
|
"""
|
|
Tears down all of the fixtures.
|
|
|
|
Returns true if all fixtures were torn down successfully, and
|
|
false otherwise.
|
|
"""
|
|
success = True
|
|
for job in self._jobs:
|
|
try:
|
|
if not job.fixture.teardown(finished=True):
|
|
self.logger.warn("Teardown of %s was not successful.", job.fixture)
|
|
success = False
|
|
except:
|
|
self.logger.exception("Encountered an error while tearing down %s.", job.fixture)
|
|
success = False
|
|
return success
|
|
|
|
def _make_fixture(self, job_num, job_logger):
|
|
"""
|
|
Creates a fixture for a job.
|
|
"""
|
|
|
|
fixture_config = {}
|
|
fixture_class = fixtures.NOOP_FIXTURE_CLASS
|
|
|
|
if self.fixture_config is not None:
|
|
fixture_config = self.fixture_config.copy()
|
|
fixture_class = fixture_config.pop("class")
|
|
|
|
fixture_logger = job_logger.new_fixture_logger(fixture_class)
|
|
|
|
return fixtures.make_fixture(fixture_class, fixture_logger, job_num, **fixture_config)
|
|
|
|
def _make_hooks(self, job_num, fixture):
|
|
"""
|
|
Creates the custom behaviors for the job's fixture.
|
|
"""
|
|
|
|
behaviors = []
|
|
|
|
for behavior_config in self.hooks_config:
|
|
behavior_config = behavior_config.copy()
|
|
behavior_class = behavior_config.pop("class")
|
|
|
|
hook_logger = self.logger.new_hook_logger(behavior_class, fixture.logger)
|
|
behavior = _hooks.make_custom_behavior(behavior_class,
|
|
hook_logger,
|
|
fixture,
|
|
**behavior_config)
|
|
behaviors.append(behavior)
|
|
|
|
return behaviors
|
|
|
|
def _make_job(self, job_num):
|
|
"""
|
|
Returns a Job instance with its own fixture, hooks, and test
|
|
report.
|
|
"""
|
|
job_logger = self.logger.new_job_logger(self._suite.test_kind, job_num)
|
|
|
|
fixture = self._make_fixture(job_num, job_logger)
|
|
hooks = self._make_hooks(job_num, fixture)
|
|
|
|
report = _report.TestReport(job_logger, self._suite.options)
|
|
|
|
return _job.Job(job_logger, fixture, hooks, report, self._suite.options)
|
|
|
|
def _make_test_queue(self):
|
|
"""
|
|
Returns a queue of TestCase instances.
|
|
|
|
Use a multi-consumer queue instead of a unittest.TestSuite so
|
|
that the test cases can be dispatched to multiple threads.
|
|
"""
|
|
|
|
test_queue_logger = self.logger.new_testqueue_logger(self._suite.test_kind)
|
|
# Put all the test cases in a queue.
|
|
queue = _queue.Queue()
|
|
for test_name in self._suite.tests:
|
|
test_case = testcases.make_test_case(self._suite.test_kind,
|
|
test_queue_logger,
|
|
test_name,
|
|
**self.test_config)
|
|
queue.put(test_case)
|
|
|
|
# Add sentinel value for each job to indicate when there are no more items to process.
|
|
for _ in xrange(len(self._jobs)):
|
|
queue.put(None)
|
|
|
|
return queue
|