"""Interface of the different fixtures for executing JSTests against."""
|
|
|
|
import os.path
|
|
import time
|
|
from enum import Enum
|
|
|
|
import pymongo
|
|
import pymongo.errors
|
|
|
|
from ... import config
|
|
from ... import errors
|
|
from ... import logging
|
|
from ... import multiversionconstants as multiversion
|
|
from ... import utils
|
|
from ...utils import registry
|
|
|
|
_FIXTURES = {} # type: ignore
|
|
|
|
|
|
class TeardownMode(Enum):
|
|
"""
|
|
Enumeration representing different ways a fixture can be torn down.
|
|
|
|
Each constant has the value of a Linux signal, even though the signal won't be used on Windows.
|
|
This class is used because the 'signal' package on Windows has different values.
|
|
"""
|
|
|
|
TERMINATE = 15
|
|
KILL = 9
|
|
ABORT = 6
|
|
|
|
|
|
def make_fixture(class_name, *args, **kwargs):
|
|
"""Provide factory function for creating Fixture instances."""
|
|
|
|
if class_name not in _FIXTURES:
|
|
raise ValueError("Unknown fixture class '%s'" % class_name)
|
|
return _FIXTURES[class_name](*args, **kwargs)
|
|
|
|
|
|
class Fixture(object, metaclass=registry.make_registry_metaclass(_FIXTURES)):
|
|
"""Base class for all fixtures."""
|
|
|
|
# We explicitly set the 'REGISTERED_NAME' attribute so that PyLint realizes that the attribute
|
|
# is defined for all subclasses of Fixture.
|
|
REGISTERED_NAME = "Fixture"
|
|
|
|
_LAST_STABLE_FCV = multiversion.LAST_STABLE_FCV
|
|
_LATEST_FCV = multiversion.LATEST_FCV
|
|
_LAST_STABLE_BIN_VERSION = multiversion.LAST_STABLE_BIN_VERSION
|
|
|
|
def __init__(self, logger, job_num, dbpath_prefix=None):
|
|
"""Initialize the fixture with a logger instance."""
|
|
|
|
if not isinstance(logger, logging.Logger):
|
|
raise TypeError("logger must be a Logger instance")
|
|
|
|
if not isinstance(job_num, int):
|
|
raise TypeError("job_num must be an integer")
|
|
elif job_num < 0:
|
|
raise ValueError("job_num must be a nonnegative integer")
|
|
|
|
self.logger = logger
|
|
self.job_num = job_num
|
|
|
|
dbpath_prefix = utils.default_if_none(config.DBPATH_PREFIX, dbpath_prefix)
|
|
dbpath_prefix = utils.default_if_none(dbpath_prefix, config.DEFAULT_DBPATH_PREFIX)
|
|
self._dbpath_prefix = os.path.join(dbpath_prefix, "job{}".format(self.job_num))
|
|
|
|
def pids(self):
|
|
"""Return any pids owned by this fixture."""
|
|
raise NotImplementedError("pids must be implemented by Fixture subclasses %s" % self)
|
|
|
|
def setup(self):
|
|
"""Create the fixture."""
|
|
pass
|
|
|
|
def await_ready(self):
|
|
"""Block until the fixture can be used for testing."""
|
|
pass
|
|
|
|
def teardown(self, finished=False, mode=None): # noqa
|
|
"""Destroy the fixture.
|
|
|
|
The fixture's logging handlers are closed if 'finished' is true,
|
|
which should happen when setup() won't be called again.
|
|
|
|
Raises:
|
|
errors.ServerFailure: If the teardown is not successful.
|
|
"""
|
|
|
|
try:
|
|
self._do_teardown(mode=mode)
|
|
finally:
|
|
if finished:
|
|
for handler in self.logger.handlers:
|
|
# We ignore the cancellation token returned by close_later() since we always
|
|
# want the logs to eventually get flushed.
|
|
logging.flush.close_later(handler)
|
|
|
|
def _do_teardown(self, mode=None): # noqa
|
|
"""Destroy the fixture.
|
|
|
|
This method must be implemented by subclasses.
|
|
|
|
Raises:
|
|
errors.ServerFailure: If the teardown is not successful.
|
|
"""
|
|
pass
|
|
|
|
def is_running(self): # pylint: disable=no-self-use
|
|
"""Return true if the fixture is still operating and more tests and can be run."""
|
|
return True
|
|
|
|
def get_dbpath_prefix(self):
|
|
"""Return dbpath prefix."""
|
|
return self._dbpath_prefix
|
|
|
|
def get_internal_connection_string(self):
|
|
"""Return the connection string for this fixture.
|
|
|
|
This is NOT a driver connection string, but a connection string of the format
|
|
expected by the mongo::ConnectionString class.
|
|
"""
|
|
raise NotImplementedError(
|
|
"get_internal_connection_string must be implemented by Fixture subclasses")
|
|
|
|
def get_driver_connection_url(self):
|
|
"""Return the mongodb connection string as defined below.
|
|
|
|
https://docs.mongodb.com/manual/reference/connection-string/
|
|
"""
|
|
raise NotImplementedError(
|
|
"get_driver_connection_url must be implemented by Fixture subclasses")
|
|
|
|
def mongo_client(self, read_preference=pymongo.ReadPreference.PRIMARY, timeout_millis=30000):
|
|
"""Return a pymongo.MongoClient connecting to this fixture with specified 'read_preference'.
|
|
|
|
The PyMongo driver will wait up to 'timeout_millis' milliseconds
|
|
before concluding that the server is unavailable.
|
|
"""
|
|
|
|
kwargs = {"connectTimeoutMS": timeout_millis}
|
|
if pymongo.version_tuple[0] >= 3:
|
|
kwargs["serverSelectionTimeoutMS"] = timeout_millis
|
|
kwargs["connect"] = True
|
|
|
|
return pymongo.MongoClient(host=self.get_driver_connection_url(),
|
|
read_preference=read_preference, **kwargs)
|
|
|
|
def __str__(self):
|
|
return "%s (Job #%d)" % (self.__class__.__name__, self.job_num)
|
|
|
|
def __repr__(self):
|
|
return "%r(%r, %r)" % (self.__class__.__name__, self.logger, self.job_num)
|
|
|
|
|
|
class ReplFixture(Fixture):
|
|
"""Base class for all fixtures that support replication."""
|
|
|
|
REGISTERED_NAME = registry.LEAVE_UNREGISTERED # type: ignore
|
|
|
|
AWAIT_REPL_TIMEOUT_MINS = 5
|
|
AWAIT_REPL_TIMEOUT_FOREVER_MINS = 24 * 60
|
|
|
|
def get_primary(self):
|
|
"""Return the primary of a replica set."""
|
|
raise NotImplementedError("get_primary must be implemented by ReplFixture subclasses")
|
|
|
|
def get_secondaries(self):
|
|
"""Return a list containing the secondaries of a replica set."""
|
|
raise NotImplementedError("get_secondaries must be implemented by ReplFixture subclasses")
|
|
|
|
def retry_until_wtimeout(self, insert_fn):
|
|
"""Retry until wtimeout reached.
|
|
|
|
Given a callback function representing an insert operation on
|
|
the primary, handle any connection failures, and keep retrying
|
|
the operation for up to 'AWAIT_REPL_TIMEOUT_MINS' minutes.
|
|
|
|
The insert operation callback should take an argument for the
|
|
number of remaining seconds to provide as the timeout for the
|
|
operation.
|
|
"""
|
|
|
|
deadline = time.time() + ReplFixture.AWAIT_REPL_TIMEOUT_MINS * 60
|
|
|
|
while True:
|
|
try:
|
|
remaining = deadline - time.time()
|
|
insert_fn(remaining)
|
|
break
|
|
except pymongo.errors.ConnectionFailure:
|
|
remaining = deadline - time.time()
|
|
if remaining <= 0.0:
|
|
message = "Failed to connect to {} within {} minutes".format(
|
|
self.get_driver_connection_url(), ReplFixture.AWAIT_REPL_TIMEOUT_MINS)
|
|
self.logger.error(message)
|
|
raise errors.ServerFailure(message)
|
|
except pymongo.errors.WTimeoutError:
|
|
message = "Replication of write operation timed out."
|
|
self.logger.error(message)
|
|
raise errors.ServerFailure(message)
|
|
except pymongo.errors.PyMongoError as err:
|
|
message = "Write operation on {} failed: {}".format(
|
|
self.get_driver_connection_url(), err)
|
|
raise errors.ServerFailure(message)
|
|
|
|
|
|
class NoOpFixture(Fixture):
|
|
"""A Fixture implementation that does not start any servers.
|
|
|
|
Used when the MongoDB deployment is started by the JavaScript test itself with MongoRunner,
|
|
ReplSetTest, or ShardingTest.
|
|
"""
|
|
|
|
REGISTERED_NAME = "NoOpFixture"
|
|
|
|
def pids(self):
|
|
""":return: any pids owned by this fixture (none for NopFixture)."""
|
|
return []
|
|
|
|
def mongo_client(self, read_preference=None, timeout_millis=None):
|
|
"""Return the mongo_client connection."""
|
|
raise NotImplementedError("NoOpFixture does not support a mongo_client")
|
|
|
|
def get_internal_connection_string(self):
|
|
"""Return the internal connection string."""
|
|
return None
|
|
|
|
def get_driver_connection_url(self):
|
|
"""Return the driver connection URL."""
|
|
return None
|
|
|
|
|
|
class FixtureTeardownHandler(object):
|
|
"""A helper class used to teardown nodes inside a cluster and keep track of errors."""
|
|
|
|
def __init__(self, logger):
|
|
"""Initialize a FixtureTeardownHandler.
|
|
|
|
Args:
|
|
logger: A logger to use to log teardown activity.
|
|
"""
|
|
self._logger = logger
|
|
self._success = True
|
|
self._message = None
|
|
|
|
def was_successful(self):
|
|
"""Indicate whether the teardowns performed by this instance were all successful."""
|
|
return self._success
|
|
|
|
def get_error_message(self):
|
|
"""Retrieve the combined error message for all the teardown failures.
|
|
|
|
Return None if all the teardowns were successful.
|
|
"""
|
|
return self._message
|
|
|
|
def teardown(self, fixture, name, mode=None): # noqa: D406,D407,D411,D413
|
|
"""Tear down the given fixture and log errors instead of raising a ServerFailure exception.
|
|
|
|
Args:
|
|
fixture: The fixture to tear down.
|
|
name: The name of the fixture.
|
|
Returns:
|
|
True if the teardown is successful, False otherwise.
|
|
"""
|
|
try:
|
|
self._logger.info("Stopping %s...", name)
|
|
fixture.teardown(mode=mode)
|
|
self._logger.info("Successfully stopped %s.", name)
|
|
return True
|
|
except errors.ServerFailure as err:
|
|
msg = "Error while stopping {}: {}".format(name, err)
|
|
self._logger.warning(msg)
|
|
self._add_error_message(msg)
|
|
self._success = False
|
|
return False
|
|
|
|
def _add_error_message(self, message):
|
|
if not self._message:
|
|
self._message = message
|
|
else:
|
|
self._message = "{} - {}".format(self._message, message)
|